DIGITAL MULTIMETER DT4224


Key Features
- Achieving a high level of safety in a compact body and lightweight design
- Circuit breaker false trip prevention function helps avoid accidents resulting from breakers that mistakenly trip due to incorrect input
- More convenient function: Resistance, Capacitance measurement and diode testing (DT4224)
- Robust design capable of withstanding a drop from a height of 1 m
- Test leads conveniently wrap around the back
- ±0.5% DC V basic accuracy, wide 40 Hz to 1 kHz AC V frequency characteristics
- Low-pass filter cuts high harmonics (when measuring inverter fundamental waveforms)
- Broad -10°C (14°F) to 65°C (149°F) operating temperature range
- Display backlight
Model No. (Order Code)
DT4224 | With resistance measurement, for electrical work |
---|
DIGITAL MULTIMETER DT4224
₹13,600.00₹10,473.00Request a Call Back
- Delivery & Return
Delivery
We ship to all india, All orders are shipped with a UPS tracking number. Always free shipping for orders over Rs 1000. During sale periods and promotions the delivery time may be longer than normal.Return
I've still not received the refund to my bank account. Why? If you have received a mail from us confirming your refund request then rest assured that we have initiated your refund request and are following up with financial organisations for the same. Sometimes financial organisations take a longer time to process the refund request. However, if the refund hasn't happened by the date we promised, you can contact us. We will gladly help you. When are Refunds provided? We work to provide the most hassle-free online shopping experience. You are covered and your money safe. We initiate the refund process as soon as we receive the details Damaged products are returned to our warehouse and has been quality checked. I paid the amount upfront while purchasing product from Click Tech Engineers Pvt Ltd, how do I get the refund? Your payment is secured In case of prepaid orders (paid through credit card/debit card/net banking), the amount is refunded in the same account as you had made payment from within 7-10 working days I paid cash on delivery, how would I get the refund? if the mode of payment was cash on delivery (COD), we will initiate a NEFT bank transfer to your bank account Click Tech Engineers Pvt Ltd will contact you for your bank account details it normally takes 7-10 days for your money to get reflected in your bank account What are the details vou renuire to nmcess NFFT refund? Once you agree for NEFT refund, you will receive an email from Click Tech Engineers Pvt Ltd customer support team asking for. Bank Name Account Number Account Holder's name IFSC code Location of the Bank We initiate refund process as soon as we receive the details from you and it takes 7-10 working days for the money to be credited to your account.Help
Give us a shout if you have any other questions and/or concerns. Email: connect@clikorder.com Phone: 011 6931 1503 - Ask a Question
DIGITAL MULTIMETER DT4224
₹13,600.00₹10,473.00Ask a Question
₹13,600.00 ₹10,473.00





The Hioki DT4200 Digital Multimeter Series consists of a diverse array of meters ranging from professional to industrial to pocket meters, delivering a super fast response rate and safety features that take electrical testing to a higher level. The Hioki DT4223 is a pocket-sized digital multimeter featuring an innovating circuit-breaker false trip prevention function to enhance testing safety and a built-in voltage detector, ideal for electrical inspections.
CAT IV 300 V, CAT III 600 V
Introduction of voltage input protection functionality
This functionality keeps errors in instrument configuration from resulting in an electrical accident. Even if the instrument’s rotary switch is mistakenly set to the resistance function when attempting to measure voltage, placing the probes in contact with the circuit under measurement will not cause a tripped circuit breaker or electrical arcing.
Key Features
Basic specifications
DC Voltage range | 600.0 mV to 600.0 V, 4 ranges, Basic accuracy: ±0.5 % rdg. ±5 dgt. | |||||
---|---|---|---|---|---|---|
AC Voltage range | 6.000 V to 600.0 V, 3 ranges, Frequency characteristics: 40 Hz - 1 kHz Basic accuracy 40 - 500 Hz : ±1.0 % rdg. ±3 dgt. (True RMS, crest factor 3) | |||||
Resistance range | 600.0 Ω to 60.00 MΩ, 6 ranges Basic accuracy: ±0.9 % rdg. ±5 dgt. | |||||
Capacitance range | 1.000 μF to 10.00 mF, 5 ranges, Basic accuracy: ±1.9 % rdg. ±5 dgt. | |||||
Frequency range | AC V measurement: 99.99 Hz (5 Hz or more) to 9.999 kHz, 3 ranges Basic accuracy: ±0.1 % rdg. ±2 dgt. | |||||
Continuity check | Continuity threshold [ON]: 25 Ω or less (buzzer sound), [OFF]: 245 Ω or more Response time: 0.5 ms or more | |||||
Diode test | Open terminal voltage: 2.5 V or less, Testing current 0.5 mA or less, Threshold of forward voltage: 0.15 V to 1.5 V | |||||
Voltage detection | N/A | |||||
Other functions | Circuit-breaker false trip prevention function, filter function, display value hold, relative value display, auto-power save | |||||
Display | Main and Sub displays: 4-digits LCD, max. 6000 digits, bar graph | |||||
Display refresh rates | 5 times/s (Capacitance measurement: 0.05 to 5 times/s, depending on measured value, Frequency: 1 to 2 time/s ) | |||||
Power supply | LR03 alkaline batteries ×1, Continuous use: 35 hours (backlight OFF) | |||||
Dimensions and mass | 72 mm (2.83 in)W × 149 mm (5.87 in)H× 38 mm (1.50 in)D,190 g (6.7 oz) (including batteries and holster) | |||||
Included accessories | Test lead DT4911 ×1, Holster ×1, Instruction manual ×1, LR03 alkaline battery ×1 |
Based on 0 reviews
|
|
0% |
|
|
0% |
|
|
0% |
|
|
0% |
|
|
0% |
- IR Thermometers
- HIPOT TESTER
- Insulation Resistance Tester
- Battery Testers
- Calibration Instruments
- Clamp Multimeters
- DC Resistance Tester
- Digital Multimeter
- (PV) System Maintenance
- ANALOG MΩ HiTESTER
- Digital Insulation Tester
- DMM
- Earth Tester
- Infrared Thermometer
- Magnetic Field
- Phase Detector
- Power Quality Analyzers
- Voltage Detection
Related Products
Key features
- Audible and visual alarm for incorrect connections
- Test leads with fines tips for circuit board testing
- Simple interface to wake meter from sleep mode by activating any buttons
- Voltage: 6000-count reading
- Capacitance range: 2000uF
- Safety rating: CATIII 600V
Key features
- Audible and visual alarm for incorrect connections
- Test leads with fines tips for circuit board testing
- Simple interface to wake meter from sleep mode by activating any buttons
- Voltage: 6000-count reading
- Capacitance range: 2000uF
- Safety rating: CATIII 600V
- Frequency and temperature measurement
Key Features
- 60000 count, 5-digit display, high-resolution measurements
- ±0.025% DC V basic accuracy, wide 20 Hz to 100 kHz AC V frequency characteristics
- Low-pass filter cuts high harmonics (when measuring inverter fundamental waveforms)
- Terminal shutter mechanism (prevents erroneous test lead insertion)
- Measure up to 10 A with direct input (DT4282 only)
- Dual display lets you check voltage and frequency simultaneously
Model No. (Order Code)
DT4282 | 10 A direct input |
---|
Key features
- Share results with your team using ShareLive™ video call (requires ir3000 FC wireless connector [sold separately] and no-cost Fluke Connect mobile app).
- TrendCapture graphically displays logged data session to quickly determine whether anomalies may have occurred.
- Zoom on trend provides unprecedented ability to view and analyze TrendCapture data; zoom in up to 14 times.
- Selectable AC filter (smoothing mode) helps display a steadier reading when the input signal is changing rapidly or noisy.
- Low Pass filter for accurate voltage and frequency measurements at the same time on adjustable speed motor drives and other electrically noisy equipment.
- LoZ Volts. Low impedance voltage function for eliminating ghost voltages. Also recommended when testing for absence or presence of live power.
- Adjustable recording and auto hold thresholds, specify a percentage change in the readings that begins a new event.
- Large 50,000 count, 1/4 VGA dot matrix display with white backlight.
- Measure up to 10 A (20 A for 30 seconds).
- 100 mF capacitance range.
Key features
- Identify complex signal problems fast
- Supports accurate measurements on VFDs using a low-pass filter
- Captures intermittents as fast as 250 µS with Peak Capture
Key features
- Audible and visual alarm for incorrect connections
- Test leads with fines tips for circuit board testing
- Simple interface to wake meter from sleep mode by activating any buttons
- Voltage: 6000-count reading
- Capacitance range: 2000uF
- Safety rating: CATIII 600V
Key features
- True-rms ac voltage for accurate measurements on non-linear signals
- Resistance and continuity
- Large white LED backlight to work in poorly lit areas
Key features
- 1000V AC/DC; 10A AC/DC (with test leads and current jacks); resistance to 50 MΩ; capacitance to 10,000 μF, frequency to 100 kHz; temperature from -40 ℃ to 400 ℃
- Robust, fast and accurate with manual and automatic ranging, Display Hold, Auto Hold, and Min/Max-Average recording
- Backlit digital display, analog bar graph, and built-in temperature measurements with included thermocouple.
Key Features
- Achieving a high level of safety in a compact body and lightweight design
- Circuit breaker false trip prevention function helps avoid accidents resulting from breakers that mistakenly trip due to incorrect input
- Resistance measurement and voltage detection function (DT4223)
- Robust design capable of withstanding a drop from a height of 1 m
- Test leads conveniently wrap around the back
- ±0.5% DC V basic accuracy, wide 40 Hz to 1 kHz AC V frequency characteristics
- Low-pass filter cuts high harmonics (when measuring inverter fundamental waveforms)
- Broad -10°C (14°F) to 65°C (149°F) operating temperature range
- Display backlight
Model No. (Order Code)
DT4223 | With resistance measurement, for electrical work |
---|
Key features
- CAT III 600 V safety rating
- Current and voltage measurements
- Measures resistance and continuity to check for broken wires
- Data hold and backlit display to keep you working safe and fast
- Basic dc accuracy 0.5%
- CAT III 600 V safety rated
- Diode and continuity test with buzzer
- Small lightweight design for one-handed use
- Rugged, durable design
- Automatic shutdown
- Battery is easy to replace
Key features
- True-RMS digital multimeter with the features professional technicians prefer
- Increases productivity with manual and automatic ranging, Display Hold, Auto Hold, and Min/Max-average recording
- Measures AC and DC voltage to 1000 V
- Delivers accurate True-RMS AC current and voltage plus frequency, capacitance, resistance, continuity and diode measurements
- Safety rated CAT III 1000 V, CAT IV 600 V
Reviews
There are no reviews yet.