  • Enables high voltage measurement up to CAT Ⅲ 2000 V
  • Safely measure solar installations like the mega-solar without interrupting the grid
  • Connects to compatible Hioki clamp meters and digital multimeters (DMMs)

Model No. (Order Code)

P2000
  • DC HIGH VOLTAGE PROBE P2000

    10,909.00

    Request a Call Back

    •  Delivery & Return

      Delivery

      We ship to all india, All orders are shipped with a UPS tracking number. Always free shipping for orders over Rs 1000. During sale periods and promotions the delivery time may be longer than normal.

      Return

      I've still not received the refund to my bank account. Why? If you have received a mail from us confirming your refund request then rest assured that we have initiated your refund request and are following up with financial organisations for the same. Sometimes financial organisations take a longer time to process the refund request. However, if the refund hasn't happened by the date we promised, you can contact us. We will gladly help you. When are Refunds provided? We work to provide the most hassle-free online shopping experience. You are covered and your money safe. We initiate the refund process as soon as we receive the details Damaged products are returned to our warehouse and has been quality checked. I paid the amount upfront while purchasing product from Click Tech Engineers Pvt Ltd, how do I get the refund? Your payment is secured In case of prepaid orders (paid through credit card/debit card/net banking), the amount is refunded in the same account as you had made payment from within 7-10 working days I paid cash on delivery, how would I get the refund? if the mode of payment was cash on delivery (COD), we will initiate a NEFT bank transfer to your bank account Click Tech Engineers Pvt Ltd will contact you for your bank account details it normally takes 7-10 days for your money to get reflected in your bank account What are the details vou renuire to nmcess NFFT refund? Once you agree for NEFT refund, you will receive an email from Click Tech Engineers Pvt Ltd customer support team asking for. Bank Name Account Number Account Holder's name IFSC code Location of the Bank We initiate refund process as soon as we receive the details from you and it takes 7-10 working days for the money to be credited to your account.

      Help

      Give us a shout if you have any other questions and/or concerns. Email: connect@clikorder.com Phone: 011 6931 1503
    •  Ask a Question

      DC HIGH VOLTAGE PROBE P2000

      10,909.00

      Ask a Question

        Estimated Delivery: Dec 03 – Dec 07
        ... people are viewing this right now
        Ask a Question

        Share
      Guaranteed Safe CheckoutTrust

      10,909.00

      +

      Check Availability At

      Pincode field should not be empty!

      Excluding entire probe and cable

      The voltage of the solar installations (also known as photovoltaic or PV installations) increases to reduce cost and improve the efficiency of solar equipment. As a result, it is important to select measuring instruments that support higher voltage measurement to protect the safety of inspection workers.
      The P2000 enables high voltage measurement up to CAT III 2000 V by simply connecting to a compatible Hioki clamp meter or digital multimeter (DMM).

      Basic specifications

      Accuracy guaranteed: 1 year
      Maximum input voltage (*1) DC 2000 V
      Maximum rated line-to-ground voltage 1000 V (Measurement Category IV), Anticipated transient overvoltage 12000 V 2000 V (Measurement Category III), Anticipated transient overvoltage 15000 V
      Input resistance 20 MΩ ±5.0% (between INPUT H and INPUT L, when OUTPUT terminal is open)
      Overload protection 2200 V DC/2200 V AC (applied for 1 minute) (between INPUT H and INPUT L) 600 V DC/600 V AC (applied for 1 minute) (between OUTPUT H and OUTPUT L)
      OUTPUT terminal 4 mm banana terminal
      Operating temperature and humidity range Temperature: -25°C to 65°C (-13°F to 149°F) Humidity: −25°C to 40°C (−13°F to 104°F): 80% RH or less (non-condensing) 40°C to 65°C (104°F to 149°F): Linearly reduces from 80% RH or less at 40°C (104°F) to 25% RH or less at 65°C (149°F) (non-condensing)
      Storage temperature and humidity range -30°C to 70°C (-22°F to 158°F) 90% RH or less (non-condensing)
      Standards EN 61010
      Included accessories Connection Cable Set L4943 ×1, Strap with buckle ×2, Strap ×1, Carrying Case C0205 ×1, Instruction Manual ×1, Operating Precautions ×1

      Accuracy table for compatible instruments

      Model Combined accuracy
      DT4261 Range 600.0 V: Combined accuracy ±0.5% rdg ±0.2 V Range 2000 V: Combined accuracy ±0.5% rdg ±5 V
      CM4141-50 CM4371-50 CM4373-50 CM4375-50 Range 600.0 V: Combined accuracy ±1.0% rdg ±0.3 V Range 2000 V: Combined accuracy ±1.0% rdg ±3 V
      DT4281 DT4282 Range 60.000 V: Combined accuracy ±0.8% rdg ±0.002 V (output rate 1/10) Range 600.00 V: Combined accuracy ±0.8% rdg ±0.02 V (output rate 1/10)
      DT4252 DT4253 Range 60.00 V: Combined accuracy ±1.2% rdg ±0.05 V (output rate 1/10) Range 600.0 V: Combined accuracy ±1.2% rdg ±0.5 V (output rate 1/10)
      DT4255 DT4256 Range 60.00 V: Combined accuracy ±1.2% rdg ±0.03 V (output rate 1/10) Range 600.0 V: Combined accuracy ±1.2% rdg ±0.3 V (output rate 1/10)
      • *1:Maximum rated voltage between INPUT H and INPUT L

      Based on 0 reviews

      0.00 Overall
      0%
      0%
      0%
      0%
      0%
      Be the first to review “DC HIGH VOLTAGE PROBE P2000”

      Your email address will not be published. Required fields are marked *

      Write a review

      Reviews

      There are no reviews yet.

      No more offers for this product!
      Category:
      Close My Cart
      Close Wishlist
      Close Recently Viewed
      Close
      Close
      Categories