AC/DC CLAMP METER CM4375-50


Key Features
- CAT IV 600 V, CAT III 1000 V
When using P2000: CAT III 2000 V, CAT IV 1000 V - Easily get into tight spaces between cables thanks to thin sensor structure
- Measure DC voltages of up to 2000 V (*1) for open voltage inspections of solar panels
- Automatic AC/DC function helps boost work efficiency, Measure up to 1000 A
- Simultaneously measure inrush current in RMS and crest values
- Easily transfer measurement data to your smartphone or tablet by using our free app GENNECT Cross or to an Excel® file. (*2)
- Harmonic analysis from 1st to 30th order with GENNECT Cross (*2)
- *1:When using the optional DC High Voltage Probe P2000. The clamp meter itself is capable of measuring up to 1000 V DC.
- *2:Wireless Adapter Z3210 is necessary.
Model No. (Order Code)
CM4375-50 | Wireless Adapter Z3210 not included |
---|---|
CM4375-90 | Bundled with the Wireless Adapter Z3210 |
CM4375-91 | DC High Voltage Probe P2000 Kit |
CM4375-92 | DC High Voltage Probe P2000 + Wireless Adapter Z3210 Kit |
AC/DC CLAMP METER CM4375-50
₹48,564.00₹41,128.00Request a Call Back
- Delivery & Return
Delivery
We ship to all india, All orders are shipped with a UPS tracking number. Always free shipping for orders over Rs 1000. During sale periods and promotions the delivery time may be longer than normal.Return
I've still not received the refund to my bank account. Why? If you have received a mail from us confirming your refund request then rest assured that we have initiated your refund request and are following up with financial organisations for the same. Sometimes financial organisations take a longer time to process the refund request. However, if the refund hasn't happened by the date we promised, you can contact us. We will gladly help you. When are Refunds provided? We work to provide the most hassle-free online shopping experience. You are covered and your money safe. We initiate the refund process as soon as we receive the details Damaged products are returned to our warehouse and has been quality checked. I paid the amount upfront while purchasing product from Click Tech Engineers Pvt Ltd, how do I get the refund? Your payment is secured In case of prepaid orders (paid through credit card/debit card/net banking), the amount is refunded in the same account as you had made payment from within 7-10 working days I paid cash on delivery, how would I get the refund? if the mode of payment was cash on delivery (COD), we will initiate a NEFT bank transfer to your bank account Click Tech Engineers Pvt Ltd will contact you for your bank account details it normally takes 7-10 days for your money to get reflected in your bank account What are the details vou renuire to nmcess NFFT refund? Once you agree for NEFT refund, you will receive an email from Click Tech Engineers Pvt Ltd customer support team asking for. Bank Name Account Number Account Holder's name IFSC code Location of the Bank We initiate refund process as soon as we receive the details from you and it takes 7-10 working days for the money to be credited to your account.Help
Give us a shout if you have any other questions and/or concerns. Email: connect@clikorder.com Phone: 011 6931 1503 - Ask a Question
AC/DC CLAMP METER CM4375-50
₹48,564.00₹41,128.00Ask a Question
₹48,564.00 ₹41,128.00




CM4375-50 Product Introduction | 1000 A AC/DC Clamp Meter
Hioki clamp on meters are best-in-class measuring devices incorporating Hioki’s expertise in current sensing technology. The CM4375-50 is a 1000 A AC/DC True RMS clamp meter that features a uniquely designed slim jaw that lets you easily get into the narrow gaps between cables in crowded electrical distribution boxes without fear of damaging the cables or the clamp meter. The broad IP54 dustproof and waterproof enclosure to enable professionals to work quickly in challenging situations including the development, repair, and maintenance of equipment and devices such as electric vehicles. Additionally, the high-voltage DC measurement capability of up to 2000 V (*1) is ideal for the clamp maintenance inspections of electrical and solar power equipment.
Basic specifications
DC Current range | 1000 A, (Max. display 999.9 A) , Basic accuracy: ±1.3% rdg. ±0.3 A (at 30.1 A - 999.9 A) |
---|---|
AC Current range | 1000 A (Max. display 999.9 A, 10 Hz to 1 kHz, True RMS), Basic accuracy 45-66 Hz: ±1.8% rdg. ±0.3 A (at 30.1 A - 900.0 A) |
Crest factor | 1000 A range: 1.5 |
DC+AC Current range | 1000 A (DC, 10 Hz to 1 kHz, True RMS), Basic accuracy DC, 45-66 Hz: ±1.3% rdg. ±1.3 A (at 30.1 A - 900.0 A) |
DC Power range | 0.000 kVA to 1000 kVA (When using P2000: 0 kVA to 2000 kVA) (Automatically switched based on voltage range), Basic accuracy: ±2.0% rdg. ±20 dgt. |
DC Voltage range | 600.0 mV to 1000 V (When using P2000: 600.0 V to 2000 V) |
AC Voltage range | 6.000 V to 1000 V, 4 ranges (15 Hz to 1 kHz, True RMS), Basic accuracy 45 - 66 Hz: ±0.9% rdg. ±0.003 V (at 6 V) |
DC+AC Voltage range | 6.000 V to 1000 V, 4 ranges, Basic accuracy DC, 45-66 Hz: ±1.0% rdg. ±0.013 V (at 6 V) |
Resistance range | 600.0 Ω to 6.000 MΩ, 5 ranges, Basic accuracy: ±0.7% rdg. ±0.5 Ω (at 600 Ω) |
Electrostatic capacity range | 1.000 μF to 1000 μF, 4 ranges, Basic accuracy: ±1.9% rdg. ±0.005 μF (at 1 μF) |
Frequency range | 9.999 Hz to 999.9 Hz, 3 ranges, Basic accuracy: ±0.1% rdg. ±0.003 Hz (at 9.999 Hz) |
Temperature (K) | -40.0°C to 400.0°C, add temperature probe accuracy to basic accuracy of ±0.5% rdg. ±3.0°C |
Harmonic levels | [With Z3210 installed] Voltage/Current harmonic levels up to 30th, Content factor, Total harmonic distortion ratio *Harmonics can be displayed with our free app GENNECT Cross. |
Other functions | Continuity check, Diode check, Automatic AC/ DC detection, DC current and DC voltage polarity detection function, MAX/MIN/AVG/ PEAK MAX/PEAK MIN value display, Low-pass filter function, Display value hold, Auto hold, Backlight, Auto power save, Buzzer sound, Zero-adjustment |
Dustproof, waterproof | IP54 (While in storage, or when measuring the current an insulated conductor. Do not use when wet.) |
Power supply | LR03 Alkaline battery ×2 Continuous use: approx. 40 hr (without Z3210 installed), approx. 20 hr. (with Z3210 installed and using wireless communications) Other conditions: 100 A AC measurement, backlight off, 23°C reference value |
Core jaw diameter | φ34 mm (1.34 in) |
Smallest dimension of jaw cross-section | 9.5 mm (0.37 in) (Range value of 44 mm (1.73 in) from the tip of the jaw) |
Dimensions and mass | 65 mm (2.56 in) W × 242 mm (9.53 in) H × 35 mm (1.38 in) D mm, 350 g (12.3 oz) |
Included accessories | Test Lead L9300, Carrying Case C0203, LR03 Alkaline battery ×2, Instruction Manual ×2, Operating Precautions ×1 |
Based on 0 reviews
|
|
0% |
|
|
0% |
|
|
0% |
|
|
0% |
|
|
0% |
- IR Thermometers
- HIPOT TESTER
- Insulation Resistance Tester
- Battery Testers
- Calibration Instruments
- Clamp Multimeters
- DC Resistance Tester
- Digital Multimeter
- (PV) System Maintenance
- ANALOG MΩ HiTESTER
- Digital Insulation Tester
- DMM
- Earth Tester
- Infrared Thermometer
- Magnetic Field
- Phase Detector
- Power Quality Analyzers
- Voltage Detection
Related Products
Key Features
- CAT IV 600 V, CAT III 1000 V
When using P2000: CAT III 2000 V, CAT IV 1000 V - Measure DC voltages of up to 2000 V (*1) for open voltage inspections of solar panels
- Simultaneously measure inrush current in RMS and crest values
- Easily transfer measurement data to your smartphone or tablet by using our free app GENNECT Cross or to an Excel® file (*2)
- Harmonic analysis from 1st to 30th order with GENNECT Cross (*2)
- Automatic AC/DC function helps boost work efficiency
Key features
- True-rms AC/DC current, voltage, temperature, frequency
- Clamp meter, test leads, K-type thermocouple and soft case
- Versatile tool performs most front-line measurement tasks
AC/DC current measurements with current ranges up to 300A
24mm in diameter of measurable conductor
Light weight & compact design
Mean value display
Sleep function
Key Features
- Accurately measure even small currents with 10 A range
- Voltage, resistance, and continuity check functions
Model No. (Order Code):3287
Key Features
- CAT IV 600 V, CAT III 1000 V
When using the P2000: CAT III 2000 V, CAT IV 1000 V - Measure DC voltages of up to 2000 V (*1) for open voltage inspections of solar panels
- Simultaneously measure inrush current in RMS and crest values
- Easily transfer measurement data to your smartphone or tablet by using our free app GENNECT Cross or to an Excel® file (*2)
- Harmonic analysis from 1st to 30th order with our free app GENNECT Cross (*2)
- Automatic AC/DC function helps boost work efficiency
*1:When using the optional DC High Voltage Probe P2000. The clamp meter itself is capable of measuring up to 1000 V DC.
*2:Wireless Adapter Z3210 is necessary.
Model No. (Order Code)
CM4371-50 | Wireless Adapter Z3210 not included |
---|---|
CM4371-90 | Bundled with the Wireless Adapter Z3210 |
Key Features
- CAT IV 600 V, CAT III 1000 V
When using P2000: CAT III 2000 V, CAT IV 1000 V - Measure DC voltages of up to 2000 V (*1) for open voltage inspections of solar panels
- Simultaneously measure inrush current in RMS and crest values
- Easily transfer measurement data to your smartphone or tablet by using our free app GENNECT Cross or to an Excel® file (*2)
- Harmonic analysis from 1st to 30th order with GENNECT Cross (*2)
- Automatic AC/DC function helps boost work efficiency
Key Features
- CAT IV 600 V, CAT III 1000 V
When using P2000: CAT III 2000 V, CAT IV 1000 V - Easily get into tight spaces between cables thanks to thin sensor with a minimum cross-section span of 11 mm
- Measure up to 2000 A AC
- AC A, AC and DC V, DC+AC V, resistance, frequency, and more
- Easily transfer measurement data to your smartphone or tablet by using our free app GENNECT Cross or to an Excel® file (*1)
- Harmonic analysis from 1st to 30th order with GENNECT Cross (*1)
- *1:Wireless Adapter Z3210 is necessary.
Model No. (Order Code)
CM4141-50 | Wireless Adapter Z3210 not included |
---|---|
CM4141-90 | Bundled with the Wireless Adapter Z3210 |
Data can be downloaded to tablets and smartphones using Hioki’s dedicated free app “GENNECT Cross,” available from the Google Play or App Store.
Key Features
- Voltage, resistance, and continuity check functions
- Use the 3288 for high current measurements such as UPS emergency batteries and train motors
Model No. (Order Code):3288-20
Key Features
- Voltage, resistance, and continuity check functions
- Use the 3288 for high current measurements such as UPS emergency batteries and train motors
Model No. (Order Code)
3288 | Average rectified |
---|---|
3288-20 | True RMS |
Key features
- High performance clamp meter that measures very low voltage and high resistance
- Measures AC and DC current to 600 A, and AC and DC voltage to 1000 V
- Measures AC current to 2500 A AC with optional iFlex flexible current probe
Reviews
There are no reviews yet.