• Filters
  • Sort by
    ...
  • -5%Limited
    Brand: 
    Clamp-on Tester CL150 (ACA, ACV, DCV, OHM, 2000A) 18,999.00
    • AC current measurement with current ranges up to 2000A
    • AC/DC voltage and resistance measurements
    • 54mm in diameter of measurable conductor
    • Mean value display
    • DC output function
    • Data hold function
    • Sleep function
    • Approved for conformity to safety standards EN61010-1,
    • EN61010-2-031, EN61010-2-032 (CAT. m 600 V, CAT. II1000 V)

    Technical Document

  • -5%Limited
    Brand: 
    TY500 Digital Multimeter 18,999.00
    • Basic Accuracy: 0.09%
    • True RMS measurement
    • Measures: AC/DCV (1kV), Amps (10A), resistance, frequency, temperature, capacitance, continuity
    • 3.5 digit, 7-segment display
    • 6,000 count with 31-segment bar graph display
    • Data, Auto & Range hold
    • Low-pass filter (LPF)
    • Maximum, minimum & average values
    • Safety standards EN61010-1, 1000V CAT III, 600V CAT IV
    • Data logging capability for up to 1,600 data points (TY530 only)

    Technical Document

  • -17%Limited
    Brand: 
    Yokogawa CA310 Volt Current Loop Calibrator 5,000.00
    • Basic Accuracy: 0.015% (Source & Measure)
    • 20 mA SIMULATE (SINK) function
    • Simultaneously supplies 24V loop power and measures output signal with high accuracy
    • HART/BRAIN comm. resistance (250Ω) embedded
    • Sub-display displays span% of the source value
    • Corresponds to various types of the source pattern
      (Step sweep/ Linear sweep/ Manual step/ Span check)

    Technical Document

  • -5%Limited
    Brand: 
    Yokogawa CA320 Thermocouple Calibrator 18,999.00
      • Corresponds to 16 types of TC standard (JIS/IEC/DIN/ASTM/GOST R)
      • Sub display displays value of voltage source and span%
      • Various types of source pattern such as step sweep/ linear sweep/ manual step/ span check
      • Corresponds to other TC types by mV source function
      • Operating temperature range from -10°C to 55°C
      • Dimension is 90mm (W) x 192mm (H) x 42mm (D)
      • EN61010-1 / EN61010-2-030 safety standard
      • Segment LCD display and LED backlight

    Technical Document

  • -10%Limited
    Brand: 
    Yokogawa CA330 RTD Process Calibrator 9,000.00
    • Corresponds to 14 types of RTD standard (JIS/IEC/GOST R)
    • Sub display displays value of resistance source and span%
    • Various types of source pattern such as step sweep/ linear sweep/ manual step/ span check
    • Corresponds to 2, 3, 4 wire & realizes RTD simulation
    • Operating temperature range from -10°C to 55°C
    • Dimension is 90mm (W) x 192mm (H) x 42mm (D)
    • EN61010-1 / EN61010-2-030 safety standard
    • Segment LCD display and LED backlight

    Technical Document

  • -10%Limited
    Brand: 
    Yokogawa CA450 Process Multimeter 9,000.00

    Loop Power and 4 to 20 mA Output function in a DMM

    • Loop check functions
    • Simultaneous 24 V loop power and mA measurement
    • HART/BRAIN mode setting with loop power (Adds 250 ohm resistance internally
    • Generation functions
      – SIMULATE (SINK) function simulates transmitters– 4-20 mA span/step/auto-step/sweep output
    • Measurement functions
    • – High accuracy signal measurement:– DC mA 0.05%/30.000 mA– Handheld DMM function– Peak Hold function for the peak voltage measurement of DCS power supply– Dedicated sensor modes for direct reading of many sensor signal types
    • Enhanced Safety—helps eliminate electric shocks
      – Current terminal shutter prevents incorrect connections
      – 1 A or more of AC/DC current can be read directly using the optional clamp probe and scaling in SENSOR mode.*1
      – Measurement categories 600 V CAT. IV, 1000 V CAT. III
    • Linking with a PC
    • DMM Communication Package can be used to save and
    • Loop check function
    • Span generation function
    • Step generation function
    • Sweep generation function
    • AC/DC Current measurement (SENSOR mode
    • Transmitter simulation function
    • Similar to the Fluke 787 & Fluke 789

    Technical Document

  • -10%Limited
    Brand: 
    Yokogawa CL220 Clamp-on AC/DC Current Clampmeter 9,000.00

    AC/DC current measurements with current ranges up to 300A
    24mm in diameter of measurable conductor
    Light weight & compact design
    Mean value display
    Sleep function

  • -10%Limited
    Brand: 
    Yokogawa CL235 True-RMS Clamp-on Tester 9,000.00
    • True-RMS display
    • AC/DC current measurements with current ranges up to 600A for AC and 1000A for DC
    • AC/DC voltage, resistance and frequency measurements 33mm in diameter of measurable conductor
    • Sleep function
    • Data hold function
    • Approved for conformity to safety standards EN61010-1,EN61010-2-031, EN61010-2-032 (CAT. III 600 V)
    • Description: True-RMS ACA, ACV, DCA, DCV
    • Method of detection: True-RMS
    • Display: LCD (Digital display: 3999 counts)
    • DC Current Range: 400/1000A
    • DC Current Resolution: 0.1A
    • Response Time: Approx. 2 second
    • Range Switching: Auto-range
    • Data hold: On all range
    • Operating temperature and humidity: 0 – 40°C, 90% RH or less (no condensation)
    • Influence of conductor position: ±2% or less
    • Circuit voltage: 600 Vrms or less
    • Withstanding voltage: 5.55 kV AC for one minute
    • Power Supply: 6F22 (006P) 9V x 1; 6LR61 x 1

    Technical Document

  • -10%Limited
    Brand: 
    Yokogawa CL320 Clamp-on Leakage Tester 9,000.00
    • Leakage current measurement with current range from 20mA to 200A
    • Light weight and compact design
    • Manual range switching and auto power-off functions
    • 24mm in diameter of measurable conductor
    • Mean value display
    • Auto power-off
    • Manual range switching
    • Approved for conformity to safety standards EN61010-1, EN61010-2-032(CAT. III 300 V)
  • -10%Limited
    Brand: 
    Yokogawa CL360 200mA/1000A Leakage Current Clamp-On Meters 9,000.00
    • Leakage current measurement with current range from 200mA to 1000A
    • Method of detection Mean Value
    • Display LCD (Digital display: 1999 counts)
    • Response Time Approx. 1 second
    • Range Switching Manual-range
    • Data hold On all range
    • Operating temperature and humidity -10 – 50°C , 80% RH or less (no condensation)
    • Safety Standard Conforms EN61010-1, EN61010-2-032
    • Circuit voltage 300 Vrms or less
    • Withstanding voltage 3.7 kV AC for one minute
    • Power Supply 6 LR61 x 1, 6F22 (006P) 9V x 1
    • Battery Life Approx. 60 hours (continuous)
    • Consumed current Approx. 5 mA
    • Diameter of measurable conductor 68 mm at maximum
    • Dimensions Approx. 129 (W) x 248 (H) x 55 (D) mm
    • Weight Approx. 570 g
    • Accessories Batteries, carrying case (93031), User’s manual
    • Peak Hold On all range

     

  • -17%Limited
    Brand: 
    Yokogawa CW10 Clamp-on Power Meter Single Phase 5,000.00
    • AC/DC Power up to 600 kW, AC/DC Voltage max. 1000 V, AC/DC Current max. 600 A
    • True RMS for AC
    • Harmonics 1st to 25th order
    • Power fluctuation using ACA Inrush and Peak hold functions
    • Frequency, Resistance, Continuity, Diode check, Power factor
    • Up to 9999 counts, approx. 37mm max. diameter of measurable conductor (the jaw opens approx. 45mm max.)
    • CATIV 600V and CATIII 1000V compliant for safety
    • Backlight on display turns on and white LED automatically illuminates front of jaw when clamping
    • Non-contact Voltage Detection (Red LED lights up on detection)
    • Easy Operation with Navigator key
    • Low Pass Filter, Phase Detection, AC / DC Auto Sense

    Technical Document

  • -9%Limited
    Brand: 
    Yokogawa TY700 [TY710] Standard Type Digital Multimeter 10,000.00
    • Highest Precision
    • Basic accuracy 0.020%
    • True RMS measurement
    • New Functions for Electronic and Industrial Use
    • Simultaneous measurement and display of DC and AC
    • Switchable RMS/MEAN detection
    • AC50mV range
    • Full Support for Data Management
    • A large-capacity logging-mode memory: 1,000 data
    • USB communication, application software (Optional DMM communication package)
    • Safe Design and Wide Temperature Range for Harsh Use
    • Conforms to safety standards EN61010-1 1000V CAT., 600V CAT.
    • Safety shutters for preventing erroneous insertion of test leads into current measurement terminals
    • Operating temperature range -20 to +55C
    • Storage temperature range -40 to +70
    • Closed Case Calibration
    • 3-year Warranty

    Technical Document

Close My Cart
Close Wishlist
Close Recently Viewed
Close
Close
Categories